The optically stimulated luminescence (OSL) and the separation efficiency of the neutron and gamma components by OSL outputs were studied for samples of anion-deficient corundum (α-Αl2O3-δ) in ceramic and single-crystal forms with various neutron converters. For OSL dosimetry in mixed gamma-neutron fields, a detector material synthesized using ceramic technology consisting of a mixture of OSL active α-Αl2O3-δ and neutron-converter 6LiF powders in a ratio of 7:3 was selected as a promising one. The lower limit of the individual dose equivalent for such material under neutron irradiation does not exceed 30 μSv, and the dose dependence is linear up to 1 Sv.

Толық мәтін

Рұқсат жабық

Авторлар туралы

R. Αbashev

Mikheev Institute of Metal Physics, Ural Branch, Russian Αcademy of Sciences

Хат алмасуға жауапты Автор.
Email: abashevrm@imp.uran.ru
Ресей, 620108 Yekaterinburg, S. Kovalevskaya str., 18

Α. Boyarincev

Mikheev Institute of Metal Physics, Ural Branch, Russian Αcademy of Sciences

Email: a.i.boyarincev@imp.uran.ru
Ресей, 620108 Yekaterinburg, S. Kovalevskaya str., 18

I. Milman

Mikheev Institute of Metal Physics, Ural Branch, Russian Αcademy of Sciences

Email: milman@imp.uran.ru
Ресей, 620108 Yekaterinburg, S. Kovalevskaya str., 18

Α. Petrakovich

Mikheev Institute of Metal Physics, Ural Branch, Russian Αcademy of Sciences

Email: petrakovich2007.an@yandex.ru
Ресей, 620108 Yekaterinburg, S. Kovalevskaya str., 18

Α. Surdo

Mikheev Institute of Metal Physics, Ural Branch, Russian Αcademy of Sciences

Email: surdo@imp.uran.ru
Ресей, 620108 Yekaterinburg, S. Kovalevskaya str., 18

Әдебиет тізімі

  1. Piesch E., Burgkhardt B. Albedo Neutron Dosimetry // Radiation protection dosimetry. 1985. V. 10. No. 1-4. P. 175—1985.
  2. Piesch E. Albedo Neutron Dosimetry // The International Journal of Applied Radiation and Isotopes. 1982. V. 33. P. 1061—1076.
  3. Yukihara E., Mittani J., Vanhavere F., Akselrod M. Development of new optically stimulated luminescence (OSL) neutron dosimeters // Radiation Measurements. 2008. V. 43. P. 309—314.
  4. Surdo A.I., Abashev R.M., Krasnoperov V.S., Milman I.I., Moiseikin E.V., Boyarintsev A.I. Automatic system of individual dosimetric control COROS-333 // Defektoskopia. 2023. No. 6. P. 73—74. (In Russsia).
  5. Van Eijk C. W. E. Neutron detection and neutron dosimetry // Radiation protection dosimetry. 2004. V. 110. No. 1-4. P. 5—13.
  6. Gibson J.A.B. The Relative Tissue Kerma Sensitivity of Thermoluminescent Materials to Neutrons // Radiation Protection Dosimetry. 1986. V. 15. No. 4. P. 253—266.
  7. STO 1.1.1.01.001.0877-2020. Equipment of an automated system for individual monitoring of a nuclear power plant. Technical requirements of the operating organization, 2020.

Қосымша файлдар

Қосымша файлдар
Әрекет
1. JATS XML
2. Fig. 1. Dependences of SOSL on thickness d for samples from α-Al2O3-δ and 6LiF (a) and SOSL_N on the dose DN of their neutron irradiation in the field of the Pu—Be source at d = 430 µm (b).

Жүктеу (195KB)

© Russian Academy of Sciences, 2024