<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE root>
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:ali="http://www.niso.org/schemas/ali/1.0/" article-type="research-article" dtd-version="1.2" xml:lang="en"><front><journal-meta><journal-id journal-id-type="publisher-id">Perm Medical Journal</journal-id><journal-title-group><journal-title xml:lang="en">Perm Medical Journal</journal-title><trans-title-group xml:lang="ru"><trans-title>Пермский медицинский журнал (сетевое издание "Perm medical journal")</trans-title></trans-title-group></journal-title-group><issn publication-format="print">0136-1449</issn><issn publication-format="electronic">2687-1408</issn><publisher><publisher-name xml:lang="en">Eco-Vector</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="publisher-id">59590</article-id><article-id pub-id-type="doi">10.17816/pmj37681-88</article-id><article-categories><subj-group subj-group-type="toc-heading" xml:lang="en"><subject>Methods of diagnostics and technologies</subject></subj-group><subj-group subj-group-type="toc-heading" xml:lang="ru"><subject>Методы диагностики и технологии</subject></subj-group><subj-group subj-group-type="article-type"><subject>Research Article</subject></subj-group></article-categories><title-group><article-title xml:lang="en">Influence of suture technique in aortic valve replacement on occurrence of "Prosthesis-Patient" mismatch</article-title><trans-title-group xml:lang="ru"><trans-title>Влияние шовной техники при протезировании аортального клапана на возникновение несоответствия «Протез – пациент»</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author"><name-alternatives><name xml:lang="en"><surname>Kadyraliev</surname><given-names>B. K.</given-names></name><name xml:lang="ru"><surname>Кадыралиев</surname><given-names>Б. К.</given-names></name></name-alternatives><address><country country="RU">Russian Federation</country></address><bio xml:lang="en"><p>Candidate of Medical Sciences, cardiovascular surgeon</p></bio><bio xml:lang="ru"><p>кандидат медицинских наук, сердечно-сосудистый хирург</p></bio><email>sergeiviktorovichkucherenko@gmail.com</email><xref ref-type="aff" rid="aff1"/></contrib><contrib contrib-type="author"><name-alternatives><name xml:lang="en"><surname>Arutyunyan</surname><given-names>V. B.</given-names></name><name xml:lang="ru"><surname>Арутюнян</surname><given-names>В. Б.</given-names></name></name-alternatives><address><country country="RU">Russian Federation</country></address><bio xml:lang="en"><p>MD, PhD, Head of Cardiac Surgical Unit № 1, cardiovascular surgeon</p></bio><bio xml:lang="ru"><p>доктор медицинских наук, заведующий кардиохирургическим отделением № 1, сердечно-сосудистый хирург</p></bio><email>sergeiviktorovichkucherenko@gmail.com</email><xref ref-type="aff" rid="aff1"/></contrib><contrib contrib-type="author"><name-alternatives><name xml:lang="en"><surname>Kucherenko</surname><given-names>S. V.</given-names></name><name xml:lang="ru"><surname>Кучеренко</surname><given-names>С. В.</given-names></name></name-alternatives><address><country country="RU">Russian Federation</country></address><bio xml:lang="en"><p>resident, cardiovascular surgeon</p></bio><bio xml:lang="ru"><p>ординатор, сердечно-сосудистый хирург</p></bio><email>sergeiviktorovichkucherenko@gmail.com</email><xref ref-type="aff" rid="aff2"/></contrib><contrib contrib-type="author"><name-alternatives><name xml:lang="en"><surname>Gorbunova</surname><given-names>E. A.</given-names></name><name xml:lang="ru"><surname>Горбунова</surname><given-names>Е. А.</given-names></name></name-alternatives><address><country country="RU">Russian Federation</country></address><bio xml:lang="en"><p>student</p></bio><bio xml:lang="ru"><p>студентка</p></bio><email>sergeiviktorovichkucherenko@gmail.com</email><xref ref-type="aff" rid="aff2"/></contrib></contrib-group><aff-alternatives id="aff1"><aff><institution xml:lang="en">Sukhanov Federal Center for Cardiovascular Surgery</institution></aff><aff><institution xml:lang="ru">Федеральный центр сердечно-сосудистой хирургии имени С.Г. Суханова</institution></aff></aff-alternatives><aff-alternatives id="aff2"><aff><institution xml:lang="en">E.A. Vagner Perm State Medical University</institution></aff><aff><institution xml:lang="ru">Пермский государственный медицинский университет имени академика Е.А. Вагнера</institution></aff></aff-alternatives><pub-date date-type="pub" iso-8601-date="2020-12-28" publication-format="electronic"><day>28</day><month>12</month><year>2020</year></pub-date><volume>37</volume><issue>6</issue><issue-title xml:lang="en"/><issue-title xml:lang="ru"/><fpage>81</fpage><lpage>88</lpage><history><date date-type="received" iso-8601-date="2021-01-27"><day>27</day><month>01</month><year>2021</year></date><date date-type="accepted" iso-8601-date="2021-01-27"><day>27</day><month>01</month><year>2021</year></date></history><permissions><copyright-statement xml:lang="en">Copyright ©; 2021, Kadyraliev B.K., Arutyunyan V.B., Kucherenko S.V., Gorbunova E.A.</copyright-statement><copyright-statement xml:lang="ru">Copyright ©; 2021, Кадыралиев Б.К., Арутюнян В.Б., Кучеренко С.В., Горбунова Е.А.</copyright-statement><copyright-year>2021</copyright-year><copyright-holder xml:lang="en">Kadyraliev B.K., Arutyunyan V.B., Kucherenko S.V., Gorbunova E.A.</copyright-holder><copyright-holder xml:lang="ru">Кадыралиев Б.К., Арутюнян В.Б., Кучеренко С.В., Горбунова Е.А.</copyright-holder><ali:free_to_read xmlns:ali="http://www.niso.org/schemas/ali/1.0/"/><license><ali:license_ref xmlns:ali="http://www.niso.org/schemas/ali/1.0/">http://creativecommons.org/licenses/by-sa/4.0</ali:license_ref></license></permissions><self-uri xlink:href="https://permmedjournal.ru/PMJ/article/view/59590">https://permmedjournal.ru/PMJ/article/view/59590</self-uri><abstract xml:lang="en"><p><bold>Objective.</bold> To determine the suture technique, which provides better hemodynamic indices in aortic valve replacement. Aortic valve AV) pathology is a widespread pathology among elderly persons and since the share of them increases every year, the number of surgeries for AV replacement is growing. Many factors can influence the hemolytic characteristics of AV prosthesis including construction of cusps and supporting ring. Suture technique can also influence the hemodynamic results of AV replacement. Conventional technique for attaching mechanical valve is an interrupted sealing suture.</p> <p><bold>Materials and methods. </bold>Patients who underwent AV prosthetics isolated prosthetics, prosthetics combined with coronary artery bypass grafting, with mitral valve repair, tricuspid valve repair or aortic prosthetics) over the period from January 2015 to September 2018 were studied. All statistical calculations were fulfilled using IBM SPSS Statistics 23.0 IBM Corp., Armonk, NY).</p> <p><bold>Results. </bold>Altogether, from January 2015 to September 2018, 439 patients underwent AV prosthetics; 321 patient 73.1 %) underwent isolated AV replacement. Unsealed technique had less frequency of occurrence of “prosthesis-patient" mismatch PPM), especially in the small aortic ring compared with the other suturing techniques. The suture type was the following: sealing and figure-of-eight suture and the number of sutures more than 16 were the risk factors for moderate and severe PPM in logistic regressive analysis; the suture technique was an independent risk factor for moderate and severe PPM.</p> <p><bold>Conclusions.</bold> An interrupted mattress unsealed suture permits to implant the AV prosthesis on the native fibrous ring of the valve with less frequency of occurrence of “prosthesis-patient" mismatch and promotes improvement of hemodynamics in patients with a small fibrous ring of the aortic valve.</p></abstract><trans-abstract xml:lang="ru"><p><bold>Цель.</bold> Определить шовную технику, которая обеспечивает более хорошие гемодинамические показатели при замене аортального клапана. Патология аортального клапана АК) – распространенная патология в пожилом возрасте, а так как доля лиц данного возраста увеличивается из года в год, то и растет количество операций по протезированию АК. Многие факторы могут влиять на гемодинамические характеристики протеза АК, в том числе конструкция створок и опорного кольца. Шовная техника также может повлиять на гемодинамические результаты замены АК. Традиционной техникой для прикрепления механического клапана является узловой прокладочный шов.</p> <p><bold>Материалы и методы.</bold> Обследованы пациенты, перенесшие протезирование АК изолированное протезирование, в сочетании с коронарным шунтированием, с восстановлением митрального клапана, восстановлением трикуспидального клапана или протезированием аорты) в период с января 2015 г. по сентябрь 2018 г. Все статистические расчеты были выполнены с использованием IBM SPSS Statistics 23.0 IBM Corp., Armonk, NY).</p> <p><bold>Результаты.</bold> В общей сложности с января 2015 г. по сентябрь 2018 г. 439 пациентов перенесли протезирование АК. 321 человеку 73,1 %) осуществили изолированную замену АК. Беспрокладочная техника имела достоверно меньшую частоту встречаемости несоответствия «протез – пациент» НПП), особенно в малом кольце аорты, по сравнению с другими методами наложения швов. Тип шва: прокладочный и 8-образный, и количество швов более 16 были одномерными факторами риска для умеренного и тяжелого НПП в логистическом регрессионном анализе; метод шва был независимым фактором риска для умеренного и тяжелого НПП.</p> <p><bold>Выводы.</bold> Узловой матрацный беспрокладочный шов позволяет выполнить имплантацию протеза АК на нативное фиброзное кольцо клапана с меньшей частотой возникновения несоответствия «протез – пациент» и приводит к улучшению гемодинамики у пациентов с малым фиброзным кольцом аортального клапана.</p></trans-abstract><kwd-group xml:lang="en"><kwd>Sutures</kwd><kwd>valve</kwd><kwd>aortic</kwd><kwd>hemodynamics</kwd><kwd>technique</kwd><kwd>prosthesis-patient</kwd></kwd-group><kwd-group xml:lang="ru"><kwd>Швы</kwd><kwd>клапан</kwd><kwd>аортальный</kwd><kwd>гемодинамика</kwd><kwd>техника</kwd><kwd>протез – пациент</kwd></kwd-group><funding-group/></article-meta></front><body></body><back><ref-list><ref id="B1"><label>1.</label><mixed-citation>Ugur M., Byrne J.G., Bavaria J.E. et al. Suture technique does not affect hemodynamic performance of the small supraannular Trifecta bioprosthesis. J Thorac Cardiovasc Surg 2014; 148: 1347–1351.</mixed-citation></ref><ref id="B2"><label>2.</label><mixed-citation>Tabata M., Shibayama K., Watanabe H. et al. Simple interrupted suturing increases valve performance after aortic valve replacement with a small supra-annular bioprosthesis. J Thorac Cardiovasc Surg 2014; 147: 321–325.</mixed-citation></ref><ref id="B3"><label>3.</label><mixed-citation>Haqzad Y., Loubani M., Chaudhry M. et al. Multicentre, propensity-matched study to evaluate long-term impact of implantation technique in isolated aortic valve replacement on mortality and incidence of redo surgery. Interact Cardiovasc Thorac Surg 2016; 22: 599–605.</mixed-citation></ref><ref id="B4"><label>4.</label><mixed-citation>Zhang M., Wu Q.C. Intra-supra annular aortic valve and complete supra annular aortic valve: a literature review and hemodynamic comparison. Scand J Surg 2010; 99: 28–31.</mixed-citation></ref><ref id="B5"><label>5.</label><citation-alternatives><mixed-citation xml:lang="en">LaPar D.J., Ailawadi G., Bhamidipati C.M., et al. Use of a nonpledgeted suture technique is safe and efficient for aortic valve replacement. J Thorac Cardiovasc Surg 2011; 141: 388–393.</mixed-citation><mixed-citation xml:lang="ru">LaPar D.J., Ailawadi G., Bhamidipati C.M. et al. Use of a nonpledgeted suture technique is safe and efficient for aortic valve replacement. J Thorac Cardiovasc Surg 2011; 141: 388–393.</mixed-citation></citation-alternatives></ref><ref id="B6"><label>6.</label><citation-alternatives><mixed-citation xml:lang="en">Fallon J.M., DeSimone J.P., Brennan J.M., et al. The incidence and consequence of prosthesis-patient mismatch after surgical aortic valve replacement. Ann Thorac Surg 2018; 106: 14–22.</mixed-citation><mixed-citation xml:lang="ru">Fallon J.M., DeSimone J.P., Brennan J.M. et al. The incidence and consequence of prosthesis-patient mismatch after surgical aortic valve replacement. Ann Thorac Surg 2018; 106: 14–22.</mixed-citation></citation-alternatives></ref><ref id="B7"><label>7.</label><mixed-citation>Ugur M., Suri R.M., Daly R.C. et al. Comparison of early hemodynamic performance of 3 aortic valve bioprostheses. J Thorac Cardiovasc Surg 2014; 148: 1940–1946.</mixed-citation></ref></ref-list></back></article>
